🚿Tankless Water Heater Size Calculator

Add up the fixtures you use at the same time and we'll tell you the flow rate and power a tankless heater needs.

Hot water at the same time

You need about

273,684 BTU/hr gas

6.5 GPM at a 80°F rise

GPM

6.5

temp rise °F

80

gas BTU/hr

273,684

electric kW

76.2

Size for winter, when groundwater is coldest. Big electric units often need 2–3 dedicated 240V circuits — check your panel first.

Rather hire it out?

Compare prices from pros near you — it's free.

Get free quotes from local pros

How it works

  1. Flow rate (GPM) = sum of fixtures running at once (shower 2.5, faucet 1.5, dishwasher 1.5, washer 2.0 GPM by default).
  2. Temperature rise = desired hot water temp − groundwater temp.
  3. Gas: BTU/hr ≈ 500 × GPM × rise ÷ efficiency. Electric: kW ≈ 0.1465 × GPM × rise.

Worked example

Two showers and one faucet in the North (40°F groundwater), 120°F hot water:

  • 2 × 2.5 + 1.5 = 6.5 GPM, rise = 80°F
  • Gas at 95%: 500 × 6.5 × 80 ÷ 0.95 = 273,684 BTU/hr
  • Electric: 0.1465 × 6.5 × 80 = 76 kW (too big for most homes — gas fits better)

Questions people ask

Add the flow of every fixture you might run at the same time. Most families need 5–8 GPM.